• TEL: 0086-13083697781

double pipe heat exchanger design with counterflow or

Get Price

We can supply you need double pipe heat exchanger design with counterflow or.

(PDF) Optimal Design of Double-Pipe Heat Exchangers

Nov 10, 2020 · The entire analysis has been done by selecting an existing design of a double pipe heat exchanger with specified flow conditions at the inlet to the heat exchanger. CFD Analysis of Double Pipe Counter Flow Heat Exchanger The cooler fluid removes heat from he hotter fluid as it flows along or cross it. Different co-relation are used for the calculation for the Nusselt no. and the heat transfer coefficient. 1.1.Double Pipe Heat Exchanger:-1.2.Heat Transfer Co-efficient:-1.3 Advantages of double pipe heat exchanger:-1.4 Disadvantages of double pipe heat exchanger

Chapter 5 Heat Exchangers

For convenience the NTU relationships are given for a simple double pipe heat exchanger for parallel ow and counter ow:Parallel Flow = 1exp[NTU(1+Cr)] 1+Cr (5.18) or NTU = ln[1(1+Cr)] 1+Cr (5.19) Counter Flow = 1exp[NTU(1Cr)] 1+Cr exp[NTU(1Cr)], Cr < 1 (5.20) and = NTU 1+NTU, Cr = 1 (5.21) or NTU = 1 Cr 1 ln µ 1 Cr 1 Chapter 5 Heat ExchangersThe double pipe heat exchanger is probably one of the simplest congurations found in applications. It consists of two concentric circular tubes with one uid owing inside the inner tube and the other uid owing inside the annular space between the tubes. DESIGN AND FABRICATION OF A DOUBLE PIPE HEAT EXCHANGERA double-pipe heat exchanger, in its simplest form is just one pipe inside another larger pipe. One fluid flows through the inside pipe and the other flows through the annulus between the two pipes. The wall of the inner pipe is the heat transfer surface. In this project, a double-pipe heat exchanger was designed and fabricatedwith a copper pipe having a diameter of 15mm with length of 2m and a galvanized steel

DOUBLE-PIPE EXCHANGERS - Thermopedia

Double-pipe exchangers is the generic term covering a range of jacketed 'U' tube exchangers normally operating in countercurrent flow of two types:True Double Pipes :Single inner pipe formed into a removable 'U' or element, with either longitudinal fins or centralizing supports. DOUBLE-PIPE HEAT EXCHANGER - University of UtahAug 26, 2002 · The double-pipe heat exchanger is one of the simplest types of heat exchangers. It is called a double-pipe exchanger because one fluid flows inside a pipe and the other fluid flows between that pipe and another pipe that surrounds the first. This is a concentric tube construction. Flow in a double-pipe heat exchanger can be co-current or counter-current. There are two flow Double Pipe Heat Exchanger Manufacturers India Heat Jun 27, 2018 · 1. Counter flow 2. Parallel Flow Heat Exchanger . 1. Counter flow:-The main advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design. 2. Parallel Flow:-

Double Pipe Heat Exchanger, Double Pipe Heat Exchanger

Double pipe heat exchanger Design :JC Equipments Pvt Ltd used top rated softwares to design and best quality design engineers to design your double pipe heat exchanger. The heat exchangers are usually designed in a hairpin shape with ASME Code and will typically be either counterflow or parallel flow. 1. Double Pipe Heat ExchangersThe main advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design. 2. Parallel Flow :Parallel Flow double pipe heat exchangers are focused to handle high pressures and temperatures applications. Heat Exchanger - Types, Diagram, Working, Applications

    A double pipe heat exchanger will typically be either counterflow or parallel flow. Crossflow just doesnt work for a double pipe heat exchanger. The flow pattern and the required heat exchange duty allow calculation of the log mean temperature difference. That together with an estimated overall heat transfer coefficient allows calculation of

    Heat Exchanger Demonstration Lab Double Pipe HE

    Group 1 The Lab heat exchanger Set equipment under parallel flow conditions according to the front panel of heat exchanger, and once conditions have stabilized, take the temperature readings for the inlet and outlet thermometers of both the cold and hot fluid. Repeat the experiment using counter flow set-up on heat ex-changer. Heat Exchanger Flow:Cross flow, Parallel flow, Counter

      A double pipe heat exchanger is usually operated as a counter flow heat exchanger, as shown in the diagram at the left. A picture of a double pipe heat exchanger is shown at the right. The flow pattern in a shell and tube heat exchanger with a single tube pass will be approximately counterflow if it is long in comparison with its diameter. Parallel and Counter Flow Designs Heat Exchangers The most common arrangements for flow paths within a heat exchanger are counter-flow and parallel flow. A counter-flow heat exchanger is one in which the direction of the flow of one of the working fluids is opposite to the direction to the flow of the other fluid. In a parallel flow exchanger, both fluids in the heat exchanger flow in the same direction.

      The overall heat transfer characteristics of a double pipe

      Double pipe heat exchangers are the simplest recuperators in which heat is transferred from the hot fluid to the cold fluid through a separating cylindrical wall. It consists of concentric pipes separated by mechanical closures. The overall heat transfer characteristics of a double pipe The overall heat transfer characteristics of a double pipe heat exchanger:comparison of experimental data with predictions of standard correlations M. A. Mehrabian, M. Hemmat of Mechanical Engineering, Shahid Bahonar University of Kernlan, Iran Abstract The single phase flow and thermal performance of a double pipe heat What is Double Pipe Heat Exchanger - DefinitionHeat Exchanger Flow Direction. Heat exchangers are typically classified according to flow arrangement and type of construction. The simplest heat exchanger is one for which the hot and cold fluids move in the same or opposite directions. This heat exchanger consists of two concentric pipes of different diameters. parallel-flow arrangement.

      Double Pipe Heat Exchangers

      A primary advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counterflow pattern, which is the most efficient flow pattern. That is, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design.

      Get Price

      We can supply you need double pipe heat exchanger design with counterflow or.